FIREWALL CONVENTIONAL FIRE ALARM PANEL

Sku: 
NFW
Brand: 
Available
New
discount
FIREWALL Fire Alarm Panel combines the best technology with an elegant design, as well as a simple and intuitive interface for the prevention and detection of fires. FIREWALL complies with EN-54, offering high safety standards.

References:
NFW2K - FIREWALL 2 Zones with key
NFW4K - FIREWALL 4 Zones with key
NFW8K - FIREWALL 8 Zones with key
NFW16K - FIREWALL 16 Zones with key




Main Characteristics


Integrated 2, 4, 8, 12 e 16 zones, up to 33 detectors per zone
Smart and automatic zones
Function 'Day Mode' allows to avoid false alarms.
Powered through a battery 12VDC / 7Ah.
Auxiliary outputs per zone.
Up to 2 programmable relays.
Output supply of 24 VDC up to 500 Ma
Fire alarm output up to 500 mA.

Advantages

EN54-2/-4 (DPC) certified
Elegant design
Simple and intuitive interface with code or key access
Flush and surface mount
Low consumption
Only one battery
Benefit in insurance
Sustainable product
Compliance with RoHS
After sale support fast and professional

Highlights

Automatic test
FIREWALL has a test mode which resets the system automatically after an alarm, allowing the system to be tested by a single person.

Smart setup
The FIREWALL can be configured to adapt to any detector, manual callpoint, or termination resistor. This way, it is possible to replace another fire alarm panel by a NIBBLE FIREWALL without having to change the existing circuit.

Maintenance warning
In order to always ensure the safety of the premises, FIREWALL can notify when it’s time to perform a check-up. The maintenance period can be configured according to the user manual.

Power Supply
100 240 VAC, 50/60 Hz 45 VA
Auxiliary Output
80 VDC, 500 mA (open collector)
Standby current
60 mA
Maximum current
1 A
Fuse
Main supply 4 A
24V 1.6 A
Fire Alarm 500 mA
Fire Alarm Output
24 VDC, 500 mA
Relay contacts
250 VAC, 10 A
Zones
24 V
< 65 mA
Up to 32 conventional detectors with termination resistor in parallel of 3300 Ω, 1/4 W. (Callpoint with zener diodes in series 5V1,1/4W
Dimensions
255 mm x 360 mm x 93 mm
cables: 8 x Ø 20 mm
Battery
1x 12 VDC, 7 Ah or 2x6 VDC, 12 Ah
Declaration of Performance
Manual 2 to 8 Zones
Manual 16 Zones
Datasheet
FIREWALL VIDEO
There are no reviews for this product.

Produtos relacionados

FIREWALL-PB MANUAL CALL POINT
THUNDER OUTDOOR SIREN ALARM - DISCONTINUED
REMOTE INDICATOR
FIREWALL ACCESSORIES: KEY
APOLLO PRODUCTS - FULL RANGE
ORBIS - PRODUCT RANGE - CONVENTIONAL SYSTEM